General

Profile

hemant harlalka

  • Login: hemant.harlalka@czarmetricsystem.com
  • Registered on: 02/28/2026
  • Last sign in: 04/09/2026

Issues

open closed Total
Assigned issues 5 1 6
Reported issues 13 0 13

Projects

Project Roles Registered on
SUPREME_DCN_PROJECT manager 03/06/2026
SUPREME SAMPLE manager 03/06/2026
sample-subproject developer 03/06/2026

Activity

04/09/2026

05:43 AM SUPREME SAMPLE bug #93 (pending): PENDING AND BUG IN USER INTERFACE
# 1. LIMIT CHARACTER TO ALL THE INPUT FIELD LIKE BATCH ID , DEVICE NAME, DCN NAME = 20 CHAR
# 2. WHEN SELECTING ...
hemant harlalka

04/01/2026

10:34 AM SUPREME SAMPLE feature #87 (ongoing): MULTIPLE_BATCH_CONFIGURATION
IN MULTIPLE BATCH CONFIGURATION THEIR ARE FOUR MAIN STATE RUNNING/PAUSE , AVAILABLE/ COMPLETE , INITIALIZING /CONFI... hemant harlalka

03/27/2026

09:13 AM SUPREME SAMPLE feature #86 (ongoing): FIRMWARE_JSON_ENUM_STRCTURE
enum {
INITIALIZING,
AVAILABLE,
RUNNING,
PAUSE,
COMPLETE,
CONFIG_DISABLE,

} DEVICE_BATC...
hemant harlalka

03/12/2026

06:56 AM SUPREME SAMPLE feature #39 (pending): Modbus Register Mapping for External Devices
Modbus Register Mapping for External Devices
Overview
DCN supports multiple Modbus-compatible devices using confi...
hemant harlalka
06:55 AM SUPREME SAMPLE feature #38 (pending): Network Configuration Module DCN
Network Configuration Module
(WiFi / HTTP / MQTT / OTA)
Overview
The DCN supports flexible network connectivity ...
hemant harlalka
06:52 AM SUPREME SAMPLE feature #37 (pending): Integration of Unitech Temperature & Humidity Sensor with DCN
Overview
The DCN integrates an industrial-grade Unitech temperature and humidity sensor to monitor environmental c...
hemant harlalka
06:46 AM SUPREME SAMPLE feature #36 (ongoing): Energy Meter SELEC EM2M & EM368 Integration with DCN (ESP32)
1️⃣ Energy Meter Integration with DCN (ESP32)
Overview
The DCN integrates with the EM2M & EM368 Select Energy Met...
hemant harlalka
06:13 AM SUPREME SAMPLE support #26: Need Data for the Energy meter configuration
Batch Report Structure
o Batch ID/Name
o Start Time and End Time
o Energy Consumption Difference IF(REQIURED)
o...
hemant harlalka
05:53 AM SUPREME SAMPLE support #31: Alarm Configuration changes

///HEMANT
ALARM_LOW_THRESHOLD / ALARM_HIGH_THRESHOLD → main alarm limits
ALARM_HYS_THRESHOLD_PAR_NAME → parameter ...
hemant harlalka

03/07/2026

10:44 AM SUPREME SAMPLE feature #16 (pending): ENERGY METER SELECTION
IN EM2M SINGLE PHASE MODULE DEVICE THEIR IS NO CURRENT TRANFORMER CONFIGURATON AND CONNECTION PORT IS AVAILABLE FOR H... hemant harlalka

Also available in: Atom